원저

Clinical Application of Endoscopy Using Smartphone

Hee-June Park1, Ull-Jai Sohn2, Geun-Hyo Kim3, In-Ho Bae3, Soo-Geun Wang3, Jae-Keun Cho3, Jin-Dong Kim4,*
Author Information & Copyright
1Department of Speech Rehabilitation, Choonhae College of Health Sciences, Ulsan, Korea
2IM Co., Ltd, Busan, Korea
3Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea
3Department of Speech and Hearing Therapy, Catholic University of Pusan, Busan, Korea
*교신저자: 김진동, 46252 부산광역시 금정구 오륜대로 57 부산가톨릭대학교 언어청각치료학과 전화 :(051) 510-0844·전송:(051) 510-0848 E-mail:jdkim@cup.ac.kr

© Copyright 2016 The Busan, Ulsan, Gyeoungnam Branch of Korean Society of Otolaryngology-Head and Neck Surgery. This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Received: Mar 03, 2016; Revised: Apr 20, 2016; Accepted: May 18, 2016

Published Online: May 31, 2020

ABSTRACT

Background and Objectives: From patient monitoring and diagnostics to more efficient medical education and communication, smartphones serve a vital role in the practice of medicine today. This study was to evaluate the diagnostic capability of the smartphone installed with endoscopy adapter, as compared to the traditional endoscope, and to its investigate clinical utility. Material and Methods: This study enabled observation of internal body status using the portable light source device and camera of smartphone and rigid endoscope inside the ear, nose, and throat of adult man which cannot be directly observed with eyes of human, and obtained the image using the display and recording function of smartphone. Results: This study evaluated the photos obtained and use of endoscope examination using the smartphone. In the evaluation of photo image obtained, it obtained low score in comparison with the photo taken using the existing endoscope of clinics but no statistical significance was found. In the evaluation on use of endoscope examination using the smartphone, only ease of endoscope replacement and convenience on actual use showed statistical significance. Conclusions: In a clinical environment, satisfaction score showed relatively lower compared with the existing endoscopy, but it’s considered useful using for examination and diagnosis from U-healthcare, telemedicine, and emergency situation at low cost. (J Clinical Otolaryngol 2016;27:103-111)

Keywords: Endoscopy; Smartphone; U-health care; Mobile smart devices


37권 2호 Quiz 및 정답, 해설

정답 ③ ㄴ,ㄹ

ㄱ. 갑상선 고주파는 전극 주변에 고주파 전류가 흐르면서 조직내 이온들을 빠르게 진동시키고 
이렇게 발생한 마찰열(friction heat)을 통해 섭씨 60~100도씨의 열을 발생시켜 조직의 응고 괴사를 유도한다.

ㄴ. 생리식염수는 Na+,Cl-를 포함하여 전기전도성이 높아 5% DW 같은 비이온성 용액을 이용하는 것이 좋다.

ㄷ. 관련된 흔한 합병증은 통증, 혈종, 일시적 음성변화로 알려져 있다.

ㄹ. 갑상선 고주파절제술은 정상 갑상선조직을 최대한 보존하면서 양성결절의 부피감소를 유도하고, 
미세유두암의 완전 소실을 유도할 수 있는 치료이다.

 

* 당첨자 (5명)

권**    010-****-**85

고**    010-****-**75

서**    010-****-**72

이**    010-****-**61

장**    010-****-**64

 

응모해 주신 모든분들께 감사드립니다.

경품은 당첨자분들께 8.21(금)까지 개별 발송해 드리겠습니다.

 

임상이비인후과 편집위원회 


I don't want to open this window for a day.